GE Distribution TPL412RT PowerMark Gold™ Factory Included Ground Bar Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 4, 1/2 Inch: 4 Space, 3-Wire

Vendor:

GE Distribution

Price:

Cat #:

TPL412RT

$180.03

SKU:

178341

UPC:

783164198126

each



+Add to
Shopping List
Qty Available
  To Ship: 2 unit(s)
  Local: Check Availability
Need more than 2?
Additional inventory usually ships in 9 days.
 
Continue Shopping ADD TO CART

*Images are representative of products
listed and may not be actual product.

View Product Specifications Sheet
View Product Catalog

GE Distribution TPL412RT PowerMark Gold™ Factory Included Ground Bar Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 4, 1/2 Inch: 4 Space, 3-Wire

Product Details
Size: 7.500 Inch Width x 3.120 Inch Depth x 8.750 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground

GE Distribution PowerMark Gold™ 1-Phase 3-Wire Factory included ground bar load center has THQL/THQP type main breaker for added safety and protection. It has voltage rating of 120/240 VAC and current rating of 125 Amps. It has interrupting rating of 10 Amps. It has top/bottom feed for convenience. Load center has eight circuits, four spacing of 1-Inch and four spacing of 1/2-Inch for convenient operation. Load center has four spaces for 1-Pole/1-Inch THQL breakers and two spaces for 2-Pole/1-Inch THQL breakers. It measures 7.500 Inch x 3.120 Inch x 8.750 Inch. It has eight spaces for 1-Pole/1/2-Inch THQP breakers and three spaces for 2-Pole/1/2-Inch THQP breakers.

Load center has conductor temperature rating of 60/75 deg C. It has thermoplastic NEMA 3 enclosure to provide protection against rain and ice formation. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kAIC. It can accommodate aluminum/copper wires of size 1 - 2/0 AWG. It has plug in breaker mounting for easy installation. Load center is UL listed and GSA complaint.

Product Specifications
Amperage Rating 125
Application Residential
Brand Name GE Distribution
Cable Size 1-2/0 AWG Aluminum/Copper
Circuit Breaker Type THQL/THQP
Cover Type Without Door
Enclosure NEMA 3R Outdoor
Height 5.00
Interrupt Rating 10
Item Load Center
Length 9.56
Mounting Plug-In
Phase 1
Sub Brand PowerMark Gold™
Type Factory Included Ground Bar
Voltage Rating 120/240
Width 7.81
Wiring Configuration 3-Wire
1 In Space 4
1/2 In Space 4
Amperage 125 A
Brand / Label Components
Breaker Mounting Plug in
Bus Rating 125
Circuit Configuration 1 Phase 3 Wire
Commodity Code 3320
Construction Thermoplastic Enclosure
Device Type Main Lugs
Door Yes
Enclosure Size Designation R1
Enclosure Type NEMA 3R, Outdoor
Feed Either
Feed Location Top/Bottom
GSA Compliance YES
GTIN 00783164198126
Interrupting Rating 10 Kiloampere
Load Regulation 120/240V ac
Main Breaker Type Thql/Thqp
Main Wire Size 1 to 2/0 AWG (Aluminum/Copper)
Maximum Number of Spaces (4) 1 Pole 1 in Thql/(2) 2 Pole 1 in Thql/(8) 1 Pole 1/2 in Thqp/(3) 2 Pole 1/2 in Thqp
Mfr/Vendor GE Distribution
Model TPL
Number Of Feeders Either
Number of Spaces 1.000 Inch: 4, 1/2 Inch: 4
Product Type Load Center
ShipWeight 2.20
ShortDescriptionStripped GE-Distribution-TPL412RT-PowerMark-Gold
Socket Type 0
Special Features - UL Listed (Panelboards No. 67)
- 60%XDD/75%XDDC Conductor Rating
- Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code
- 22kAIC RMS symmetrical, Except Where Noted
- 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down
- For a listing of CSA Listed load centers, visit www.geelectrical.com
Standard UL
Standards UL Listed, GSA Compliance
UPC 783164198126
Wires 3 Wire
description GE Distribution 1-Phase 3-Wire Convertible residential load center has THQL/THQP type main breaker for added safety and protection. It has voltage rating of 120/240 VAC and current rating of 125 Amps. It has interrupting rating of 10 Amps. It has top/bottom feed for convenience. Load center has eight circuits, four spacing of 1-Inch and four spacing of 1/2-Inch for convenient operation. Load center has four spaces for 1-Pole/1-Inch THQL breakers and two spaces for 2-Pole/1-Inch THQL breakers. It has eight spaces for 1-Pole/1/2-Inch THQP breakers and three spaces for 2-Pole/1/2-Inch THQP breakers.

Load center has conductor temperature rating of 60/75 deg C. It has thermoplastic NEMA 3 enclosure to provide protection against rain and ice formation. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kAIC. It can accommodate aluminum/copper wires of size 1 - 2/0 AWG. It has plug in breaker mounting for easy installation. Load center is UL listed and GSA complaint.
eclipseId 110517
feature#1 Main Lug
feature#2 120/240 Vac
feature#3 125 Ampere
feature#4 8 Maximum Circuit(S)
feature#5 (4) 1 Pole 1 Inch Thql/(2) 2 Pole 1 Inch Thql/(8) 1 Pole 1/2 Inch Thqp/(3) 2 Pole 1/2 Inch Thqp Maximum Space(S)
feature#6 Thql/Thqp Main Breaker
feature#7 Breaker Mounting Plug In
feature#8 Interrupting Rating 10 Kiloampere
customers have also purchased