Milbank U227MTBL Ring 3-Wire Meter Main Combo With Loadcenter; 120/240 Volt AC, 200 Amp Continuous, 3-Phase, AISI A60 Sheet Steel, Surface Mount

Vendor:

Milbank

Price:

Cat #:

U227MTBL

$2,692.23

Part#:

168851

SKU:

630744

UPC:

784572177055

each



+Add to
Shopping List
Qty Available
  To Ship: 1 unit(s)
  Local: Check Availability
Need more than 1?
Additional inventory usually ships in 10 days.
 
Continue Shopping ADD TO CART

*Images are representative of products
listed and may not be actual product.

     
View Product Specifications Sheet
View Product Catalog
View Product Manufacturer Warranty

Milbank U227MTBL Ring 3-Wire Meter Main Combo With Loadcenter; 120/240 Volt AC, 200 Amp Continuous, 3-Phase, AISI A60 Sheet Steel, Surface Mount

Product Details
Dimension: 27 Inch Width x 6 Inch Depth x 30 Inch Height

Milbank Ring 3-Wire meter main combo with loadcenter measuring 27 Inch x 6 Inch x 30 Inch features twin 2 1/2 Inch closing plates hub and main disconnecting device as circuit breaker or T-fuse pullout. Meter with test block bypass switch is made of AISI A60 sheet steel and features fabricated, ASA gray baked, polyurethane powder paint finish. It features sealable utility compartment and hinged padlock door on load side. Three phase meter has voltage rating of 120/240 VAC, current rating of 200 Amps and frequency rating of 60 Hz.

Combo features 7 terminals and G90 galvanized steel with powder coat finish. It has 3 poles, 24 spaces and features single mechanical line side or load side connection. It comes with 24/42 internal circuits and surface mounting. Meter with overhead/underground cable entry features bottom conduit, back conduit knockouts and NEMA 3R rating. It is designed for meter mounting base. Combo meets UL listed, ANSI #C12.7-1987, EUSERC standards.

Product Specifications
Amperage 200 A
Amperage Rating 200 Amp Continuous
Application For Meter Mounting Base
Brand Name Milbank
Bypass Switch Type Test Block
Cable Entry Bottom Conduit - (1) 1/2 Inch - (2) 1-1/4 Inch And 1-1/2 Inch And 2 Inch And 2-1/2 Inch - (1) 2-1/2 Inch And 3 Inch (Utility Section); (11) 1/2 Inch - (2) 1/2 Inch And 3/4 Inch - (1) 1/2 Inch And 3/4 Inch And 1 Inch And 1-1/4 Inch - (2) 3/4 Inch And 1 Inch And 1-1/4 Inch And 1-1/2 Inch (Customer Section); Back Conduit - (6) 1/2 Inch - (4) 1/2 Inch And 3/4 Inch - (1) 3/4 Inch And 1 Inch And 1-1/4 Inch And 1-1/2 Inch Knockout, 2-1/2 Inch Hub
Circuit Configuration 3 Phase 4 Wire
Commodity Code 3500
Connection 7 Terminal, Single Mechanical Line Side and Single Mechanical Load Side
Dimension 27.000 Inch Width x 6.000 Inch Depth x 30.000 Inch Height
Enclosure G90 Galvanized Steel With Powder Coated Finish
Enclosure Material Asa Gray Baked Polyurethane Powder Painted Aisi A60 Sheet Steel
Finish Fabricated, ASA Gray Baked, Polyurethane Powder Paint
Frequency Rating 60
Hub Type 2-1/2 in Hub With Closing Plate
Interrupt Rating 10
Item Meter Main Combo With Loadcenter
Knockouts Yes
Main Disconnect Type QJ23B200 200 A 3 Pole 10 Kiloampere Interrupting Rating Circuit Breaker/Pullout
Material AISI A60 Sheet Steel, G90 Galvanized Steel
Mfr/Vendor Milbank
Model MTBL
Mounting Surface
NEMA Rating NEMA 3R
Number of Circuits 24/42 Internal, 24 Branch
Number of Pole Spaces 24
Number of Poles 3
Number of Spaces 24
Order Minimum 1
Phase 3
Service Type Overhead/Underground
ShortDescriptionStripped Milbank-U227MTBL-Ring-3-Wire-Meter-Main-Combo-With
Special Features 7 Terminal, Ring Type, Small Closing Plate, One 200 Ampere Main Breaker, 24 Branch Circuits
Standard UL Listed
Standards UL Listed, ANSI #C12.7-1987, Meets EUSERC
Terminal 7 Terminal, Single Mechanical Line Side and Single Mechanical Load Side
Type Ring, 3-Wire, Overhead/Underground
UPC 784572177055
Voltage Rating 120/240
description Test Block Bypass, QJ23B200 200 A 3 Pole 10 Kiloampere Interrupting Rating Circuit Breaker/Pullout Main Disconnect; Service Type Overhead/Underground; 208 VAC Star/120 Vac, 120/240 VAC Delta; 200 Ampere; Test Block Bypass Switch; 42 Circuit(S)
feature#1 QJ23B200 200 Ampere 3 Pole 10 Kiloampere Interrupting Rating Circuit Breaker/Pullout Main Disconnect
feature#2 Service Type Overhead/Underground
feature#3 208 Vac Star/120 Vac, 120/240 Vac Delta
feature#4 200 Ampere
feature#5 Test Block Bypass Switch
feature#6 42 Circuit(S)
feature#7 24 Pole Space(S)
feature#8 2-1/2 Inch Hub With Closing Plate Hub