Eaton / Cutler Hammer BR1624B100R Rainproof Main Circuit Breaker Load Center; 100 Amp, 120/240 Volt AC, 1 Phase, 16 Space, 24 Circuit, 3-Wire

*Images are representative of products listed and may not be actual product.



Ready to Ship

Need more? Additional inventory ships in 10 business days.

Add to Shopping List

Your Price
$525.37 / each

Vendor: Eaton / Cutler Hammer
Cat #: BR1624B100R
Part #: 16986
SKU: 402458
UPC #: 786676444101

Product Details

Size: 14.310 Inch Width x 5.190 Inch Depth x 21 Inch Height

Eaton BR Main circuit breaker load center features tin-plated aluminum bus and a bottom/top feed location. The 1-Phase, 3-Wire, 24-Pole load center comes with 16 spaces and has NEMA 3R outdoor rainproof enclosure. It has a voltage rating of 120/240 VAC and current rating of 100 Amps. It accommodates copper/aluminum wire of size 4 - 1 AWG at 60/75 deg C and a maximum of 24 circuits. It measures 14.310 Inch x 5.190 Inch x 21 Inch. Load center is UL listed.

Product Specifications

Amperage 100 A
Amperage Rating 100 Amp
Amps 100
Application Power Distribution
Bus Material Tin Plated Aluminum
Cable Size 4-1/0 AWG (Aluminum/Copper)
Catalog Description BR style 1-inch loadcenter, main circuit breaker, no feed-thru lugs, 100A, single-phase, 24-pole, 24 circuits, 16 spaces, 120/240V, #4-1/0 AWG Cu/Al at 600C or750C wire, NEMA 3R enclosure, c1r box size
Catalog Number BR1624B100R
Circuit Breaker Type BR
Circuit Configuration 1 Phase 3 Wire
Circuits 24
Commodity Code 3310
Competitor Part No. CUTBR1624B100R
Construction Aluminum Bus, Metallic Enclosure
Country of Origin US
Cover Type Cover included
EU RoHS Indicator C
Enclosure NEMA 3R Outdoor
Enclosure Material Metallic
Enclosure Size Designation C1R
Enclosure Type NEMA 3R, Outdoor, Rain Proof
Feed Location Bottom/Top
GTIN 00786676444101
Gross Weight 22.700
Height 6.0000
In Stock Yes
Interrupt Rating 10 Kilo-Amp
Interrupting Rating 10000 A
Invoice Description English BR style 1-inch loadcenter
Item Loadcenter
Length 22.5000
Main Breaker Type Br
Main Wire Size 4 to 1/0 AWG (Aluminum/Copper)
Maximum Number of Circuits 24
Maximum Number of Spaces (16) 1 in
Mfr/Vendor Eaton / Cutler Hammer
Model BR
Mounting Surface
NEMA Rating 3R (Outdoor Falling Rain)
Neutral Type Insulated/Bondable Split
Number Of Tandem Circuit Breaker 8
Number of Circuits 24
Number of Poles 24
Number of Spaces 16
Phase 1
Product Type Load Center
ShortDescriptionStripped Eaton-Cutler-Hammer-BR1624B100R-Rainproof-Main
Spaces 16
Special Features No feed-thru lugs
Standard UL 67; UL 50
Standards UL File #E52977, UL File #E8741, NEC 2008 Article #312.8
Type Rainproof
UPC 786676444101
Voltage Rating 120/240 Volt AC
Width 15.5000
Wiring Configuration 3-Wire
description ETN BR1624B100R BR style 1-inch loa
feature#1 Size: 14.310 Inch Width x 5.190 Inch Depth x 21.000 Inch Height