GE Distribution TLM1212RCU PowerMark Gold™ Standard Convertible Main Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 12, 1/2 Inch: 42, 24, 12, 16, 20, 40 Space, 24 Circuit, 3-Wire

*Images are representative of products listed and may not be actual product.

     

AVAILABILITY

Ready to Ship
5


Need more? Additional inventory ships in 10 business days.


Add to Shopping List

Your Price
$314.27 / each


 
Vendor: GE Distribution
Cat #: TLM1212RCU
Part #: 16572
SKU: 356388
UPC #: 783164112931

Product Details

Size: 12.880 Inch Width x 4.130 Inch Depth x 21.500 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground

GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard convertible main load center has durable copper bus construction. It has voltage rating of 120/240 VAC and current rating of 125 Amps. It has interrupting rating of 65 Kilo-Amps. It has top/bottom feed for convenience. Load center has THHQL/THQL/THQP/TQMH/TXQL type main breaker for added safety and protection. It measures 12.880 Inch x 4.130 Inch x 21.500 Inch. Load center has 24 circuits, 12 spacing of 1-Inch and 42/24/12/16/20/40 spacing of 1/2-Inch for convenient operation. Load center has 12 spaces for 1-Pole/1-Inch THQL breakers and 6 spaces for 2-Pole/1-Inch THQL breakers. It has 24 spaces for 1-Pole/0.5-Inch THQP breakers and 10 spaces for 2-Pole/0.5-Inch THQP breakers.

Load center operates at a temperature of 60/75 deg C. It has NEMA 3R outdoor enclosure to provide protection against rain and ice formation. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kilo-Amps. It can accommodate aluminum/copper wires of size 6 to 2/0 AWG. It has plug in breaker mounting for easy installation. Load center is UL listed, CSA certified and GSA compliant.

Product Specifications

1 In Space 12
1/2 In Space 42 24 12 16 20 40
Amperage 125 A
Amperage Rating 125 Amp
Application For Residential Applications
Brand / Label Components
Breaker Mounting Plug in
Bus Material Copper
Bus Rating 125 Kilo-Amp
Cable Size 6-2/0 AWG (Aluminum/Copper)
Catalog Description - UL Listed (Panelboards No. 67)
- 60n++/75n++C Conductor Rating
- Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code
- 22kAIC RMS symmetrical, Except Where Noted
- 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down
- For a listing of CSA Listed load centers, visit www.geelectrical.com
Catalog Number TLM1212RCU
Circuit Breaker Type THHQL/THQL/THQP/TQMH/TXQL
Circuit Configuration 1 Phase 3 Wire
Commodity Code 3310
Construction Copper Busbar
Country of Origin USA
Cover Type Without Door
Device Type Convertible
Door Yes
Enclosure NEMA 3R Outdoor
Enclosure Size Designation R3
Enclosure Type NEMA 3R, Outdoor
Feed Either
Feed Location Top/Bottom
GSA Compliance YES
GTIN 00783164112931
Gross Weight 20.500
Height 5.3750
In Stock Yes
Interrupt Rating 65 Kilo-Amp
Interrupting Rating 22 Kiloampere
Invoice Description English FLD CNVRTB 125A 12CRK 22K IC 3R
Item Main Lug Convertible Load Center
Length 22.0630
Load Regulation 120/240V ac
Main Breaker Type Thhql/Thql/Thqp/Tqmh/Txql
Main Wire Size 6 to 2/0 AWG (Aluminum/Copper)
Maximum Number of Circuits 24
Maximum Number of Spaces (12) 1 Pole 1 in Thql/(6) 2 Pole 1 in Thql/(24) 1 Pole 1/2 in Thqp/(10) 2 Pole 1/2 in Thqp
Mfr/Vendor GE Distribution
Model TLM
Mounting Plug-In
Number Of Feeders Either
Number of Circuits 24
Number of Spaces 1 Inch: 12, 1/2 Inch: 42, 24, 12, 16, 20, 40
Phase 1
Product Type Load Center
Select Code DISTRIBUTION EQUIP
ShipWeight 20.50
ShortDescriptionStripped GE-Distribution-TLM1212RCU-PowerMark-Gold
Socket Type 0
Special Features - UL Listed (Panelboards No. 67)
- 60%XDD/75%XDDC Conductor Rating
- Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code
- 22kAIC RMS symmetrical, Except Where Noted
- 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down
- For a listing of CSA Listed load centers, visit www.geelectrical.com
Standard UL
Standards UL Listed, GSA Compliance
Sub Brand PowerMark Gold™
Type Standard
UPC 783164112931
Voltage Rating 120/240 Volt AC
Width 13.5630
Wires 3 Wire
Wiring Configuration 3-Wire
description GE TLM1212RCU FLD CNVRTB 125A 12CRK
feature#1 Convertible Main
feature#2 120/240 Vac
feature#3 125 Ampere
feature#4 24 Maximum Circuit(S)
feature#5 (12) 1 Pole 1 Inch Thql/(6) 2 Pole 1 Inch Thql/(24) 1 Pole 1/2 Inch Thqp/(10) 2 Pole 1/2 Inch Thqp Maximum Space(S)
feature#6 Thhql/Thql/Thqp/Tqmh/Txql Main Breaker
feature#7 Breaker Mounting Plug In
feature#8 Interrupting Rating 22 Kiloampere