GE Distribution TLM3220CCU PowerMark Gold™ Standard Convertible Main Load Center; 200 Amp, 120/240 Volt AC, 1 Phase, 40 Circuit, 3-Wire, Flush/Surface

*Images are representative of products listed and may not be actual product.

     

AVAILABILITY

Ready to Ship
22


Need more? Additional inventory ships in 10 business days.


Add to Shopping List

Your Price
$431.53 / each


 
Vendor: GE Distribution
Cat #: TLM3220CCU
Part #: 83384
SKU: 356197
UPC #: 783164112764

Product Details

Size: 15.360 Inch Width x 3.750 Inch Depth x 34.560 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground

GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard convertible main load center has THQL/THQP main breaker for added safety and protection. It has voltage rating of 120/240 VAC and current rating of 200 Amps. It has interrupting rating of 65 Kilo-Amps. It has top/bottom feed for convenience. Load center has 40 circuits, 32 spacing of 1-Inch and 40/42/4/24/16/20/32 spacing of 1/2-Inch for convenient operation. It measures 15.360 Inch x 3.750 Inch x 34.560 Inch. Load center has 32 spaces for 1-Pole/1-Inch THQL breakers and 16 spaces for 2-Pole/1-Inch THQL breakers. It has 16 spaces for 1-Pole/0.5-Inch THQP breakers and 6 spaces for 2-Pole/0.5-Inch THQP breakers. It has centered key holes, slotted mounting holes and ground bar for easy installation.

Load center has optimum wire-bending space, more breaker capacity and improved safety makes it best among all other load centers. Load center operates at a temperature of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kilo-Amps. Load center has flush/surface cover to improve aesthetic look. It can accommodate 6 AWG-250 kcmil aluminum/copper wires. Load center is UL listed and CSA certified.

Product Specifications

1 In Space 32
Additional Information Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code
Amperage Rating 200 Amp
Application For Residential Applications
Breaker Mounting Plug in
Bus Material Copper
Bus Rating 200 Kilo-Amp
Cable Size 6 AWG-250 KCMIL (Aluminum/Copper)
Catalog Description - UL Listed (Panelboards No. 67)
- 60n++/75n++C Conductor Rating
- Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code
- 22kAIC RMS symmetrical, Except Where Noted
- 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down
- For a listing of CSA Listed load centers, visit www.geelectrical.com
Catalog Number TLM3220CCU
Circuit Breaker Type THQL/THQP
Circuit Configuration 1 Phase 3 Wire
Construction Copper Busbar
Country of Origin USA
Cover Type Flush/Surface
Device Type Convertible
Enclosure NEMA 1 Indoor
Enclosure Size Designation 12
Enclosure Type NEMA 1, Indoor
Feed Either
Feed Location Top/Bottom
GTIN 00783164112764
Gross Weight 33.500
Height 5.5000
In Stock Yes
Interrupt Rating 65 Kilo-Amp
Interrupting Rating 22 Kiloampere
Invoice Description English FLD CNVRTB 200A 32CRK 22K IC COMB
Item Main Lug Convertible Load Center
Length 35.2500
Load Regulation 120/240
Main Breaker Type Thql/Thqp
Main Wire Size 2/0 AWG to 250 kcmil (Aluminum)/1 AWG to 250 kcmil (Copper)
Maximum Number of Circuits 40
Maximum Number of Spaces (32) 1 Pole 1 in Thql/(16) 2 Pole 1 in Thql/(16) 1 Pole 1/2 in Thqp/(6) 2 Pole 1/2 in Thqp
Mfr/Vendor GE Distribution
Model TLM
Mounting Combination
Number Of Feeders Either
Number of Circuits 40
Number of Spaces 1 Inch: 32, 1/2 Inch: 40, 42, 4, 24, 16, 20, 32
Phase 1
Select Code DISTRIBUTION EQUIP
ShortDescriptionStripped GE-Distribution-TLM3220CCU-PowerMark-Gold
Special Features #45; UL Listed (Panelboards No. 67)#45; 60%XDD/75%XDDC Conductor Rating#45; Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code#45; 22kAIC RMS symmetrical, Except Where Noted#45; 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down#45; For a listing of CSA Listed load centers, visit www.geelectrical.com
Standard UL
Standards UL Listed
Sub Brand PowerMark Gold™
Type Standard
UPC 783164112764
Voltage Rating 120/240 Volt AC
Width 16.0000
Wiring Configuration 3-Wire
description GE TLM3220CCU FLD CNVRTB 200A 32CRK
feature#1 Convertible Main
feature#2 120/240 Vac
feature#3 40 Maximum Circuits
feature#4 (32) 1 Pole 1 Inch Thql; (16) 2 Pole 1 Inch Thql; (16) 1 Pole 1/2 Inch Thqp; (6) 2 Pole 1/2 Inch Thqp Maximum Spaces
feature#5 Centered key holes for ease of mounting
feature#6 Slotted mounting holes for adjustable depth
feature#7 Ground bar included
feature#8 Insulation tube protects ground bar from main lug wires