GE Distribution TM2410CCU PowerMark Gold™ and Plus™ Standard Main Breaker Load Center; 120/240 Volt AC, 100 Amp, 1 Inch: 24 Space, 24 Circuit, 1 Phase

*Images are representative of products listed and may not be actual product.

     

AVAILABILITY

Ready to Ship
2


Need more? Additional inventory ships in 10 business days.


Add to Shopping List

Your Price
$431.53 / each


 
Vendor: GE Distribution
Cat #: TM2410CCU
Part #: 4297
SKU: 259260
UPC #: 783164378931

Product Details

Size: 14 Inch Width x 3.750 Inch Depth x 24-11/16 Inch Height
Suitable for use as service entrance equipment when installed in accordance with the national electrical code
60 deg C/75 deg C conductor rating
Straight through main wiring
Main breaker is clearly marked and circuit numbers are stamped on front
Compact box maintains optimum wire-bending space

GE Distribution PowerMark Gold™ and Plus™ 1-Phase Main breaker load center has voltage rating of 120/240 VAC and a current rating of 100 Amps. The 3-Wire main breaker loadcenter has interrupting capacity rating of 22 kilo-Amps. It has indoor type 1, combination enclosure and accommodates 1 - 2/0 AWG size of aluminum/copper main wires. It has 24 1-Inch spaces and has combination flush/surface front type. It measures 14 Inch x 3.750 Inch x 24-11/16 Inch. Loadcenter is UL listed.

Product Specifications

1 In Space 24
1/2 In Space 0
Amperage Rating 100 Amp
Application For Residential Use
Cable Size 1-2/0 AWG (Aluminum/Copper)
Catalog Description - UL Listed (Panelboards No. 67)
- 60n++/75n++C Conductor Rating
- Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code
- 22kAIC RMS symmetrical, Except Where Noted
- 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down
- For a listing of CSA Listed load centers, visit www.geelectrical.com
Catalog Number TM2410CCU
Construction Copper Bus
Country of Origin USA
Device Type Main Breaker
Door Yes
Enclosure NEMA 1 Indoor
Feed Either
Feed Location Either
GSA Compliance NO
GTIN 00783164378931
Gross Weight 24.203
Height 5.5000
In Stock Yes
Interrupt Rating 22 Kilo-Amp
Invoice Description English 100A 24CT 1P3W 120/240V 22K IC COMB
Item Loadcenter
Length 25.1250
Load Regulation 120/240
Mfr/Vendor GE Distribution
Number Of Feeders Either
Number of Circuits 24
Number of Spaces 1 Inch: 24
Phase 1
Select Code DISTRIBUTION EQUIP
ShortDescriptionStripped GE-Distribution-TM2410CCU-PowerMark-Gold
Special Features #45; UL Listed (Panelboards No. 67)#45; 60%XDD/75%XDDC Conductor Rating#45; Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code#45; 22kAIC RMS symmetrical, Except Where Noted#45; 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down#45; For a listing of CSA Listed load centers, visit www.geelectrical.com
Standard UL
Standards UL Listed
Sub Brand PowerMark Gold™ and Plus™
Type Standard
UPC 783164378931
Voltage Rating 120/240 Volt AC
Width 16.0000
Wires 3 Wire
Wiring Configuration 3-Wire
description GE TM2410CCU 100A 24CT 1P3W 120/240
feature#1 Size: 14.000 Inch Width x 3.750 Inch Depth x 24-11/16 Inch Height
feature#2 Suitable for use as service entrance equipment when installed in accordance with the national electrical code
feature#3 60 deg C/75 deg C conductor rating
feature#4 Straight through main wiring
feature#5 Main breaker is clearly marked and circuit numbers are stamped on front
feature#6 Compact box maintains optimum wire-bending space