Phoenix Contact Phoenix 2878696 MOD BK DI8 DO4-PAC Modbus/RTU(ASCII) Bus Coupler; DIN Rail Mount

*Images are representative of products listed and may not be actual product.

     

AVAILABILITY

Ready to Ship
5


Need more? Additional inventory ships in 10 business days.


Add to Shopping List

Your Price
$482.91 / each


 
Vendor: Phoenix Contact
Cat #: 2878696
Part #: 45364
SKU: 303942
UPC #: 012596000005

Product Details

Size: 80 mm Width x 71.5 mm Depth x 119.8 mm Height
Lokalbus: Inline data jumper connection, 500 KBPS/2 MBPS transmission speed; modbus/RTU: D-SUB-9 female connector connection, 1,2 - 115,2 KBPS, 9 positions
63 maximum number of supported devices
63 maximum number of local bus devices that can be connected
8 maximum number of devices with parameter channel
Input: polarity reversal suppressor diode, output: short-circuit and overload protection free running circuit
Load: 12 VA nominal inductive, 12 Watt nominal lamp and ohmic
Complete with I/O connectors

Phoenix Bus coupler features nine positions and operates at an ambient temperature of -25 to 60 deg C. Coupler works at power supply of 0.8 Amps DC and supply voltage range of 19.2 VDC - 30 VDC at three terminals. It has 0.5 Amps DC of power supply and 19.2 VDC - 30 VDC at another terminal. It offers 24 VDC of supply from main circuit to perform effectively and has I/O supply voltage of 24 VDC. Coupler supply 19.2 VDC - 30 VDC and consume 0.98 Amp for module electronics. It has communications power of 7.5 VDC with ± 5% of accuracy. It supports 63 devices per station and eight devices per parameter channel. Coupler comprises of 61 local bus devices including two devices on board I/O's.

Coupler is a eight-input, four-output digital device and has a durable two, three-wire spring-cage connection for convenience. Input circuit has a polarity reversal suppressor diode and output circuit. It has a free running circuit to avoid overload and short-circuit. It consumes 24 VDC and has a typical response time of approximately 500 micro-seconds. It has 15 VDC - 30 VDC input voltage range "1" signal and each channel consumes 3 milli-Amps of current. Coupler offers 24 VDC of output and 2 Amps of current per module. It features inductive nominal load of 12 VA and offers 500 Amps of current per channel. It has 12 Watts of lamp and ohmic nominal load. It operates under 95% humidity and 80 - 106 kPa of air pressure.

Coupler measures 80 mm x 71.5 mm x 119.8 mm. It features a lokal bus field bus system that has transmission speed of 500 kilo-bit/second or 2 mega-bit/second. It has a in-line local bus as designation and is connected using in-line data jumper. It also features modbus/RTU field bus system and has transmission speed of 500 kbit/second or 2 Mbit/second. It has modbus/RTU as designation and is connected using D-SUB-9 female connector. It also has supply designation and is connected using 8-position in-line connector. It is stored/transported at an ambient temperature of -45 to 85 deg C, 95% humidity and 70 kPa - 106 kPa of air pressure.

Product Specifications

Amperage Rating 0.98 Amp
Degree Of Protection IP20
Environmental Conditions Storage Temperature: -45 to 85 deg C
In Stock Yes
Item Modbus/RTU(ASCII) Bus Coupler
Mfr/Vendor Phoenix Contact
Mounting DIN-Rail
Select Code MOTOR CONTROL
ShortDescriptionStripped Phoenix-Contact-Phoenix-2878696-MOD-BK-DI8-DO4-PAC
Standards UL Listed, cULus Listed, LR, GL, BV, DNV, ABS, GL-SW, LR, GL, ATEX
Temperature Rating -25 to 60 deg C
Type Lokalbus
UPC 012596000005
Voltage Rating 24 Volt DC
description Phoenix® Bus coupler features nine positions and operates at an ambient temperature of -25 to 60 deg C. Coupler works at power supply of 0.8 Amp DC and supply voltage range of 19.2 VDC - 30 VDC at three terminals. It has 0.5 Amp DC of power supply and 19.2 VDC - 30 VDC at another terminal. It offers 24 VDC of supply from main circuit to perform effectively and has I/O supply voltage of 24 VDC. Coupler supply 19.2 VDC - 30 VDC and consume 0.98 Amp for module electronics. It has communications power of 7.5 VDC with ± 5% of accuracy. It supports 63 devices per station and eight devices per parameter channel. Coupler comprises of 61 local bus devices including two devices on board I/O's.

Coupler is a eight-input, four-output digital device and has a durable two, three-wire spring-cage connection for convenience. Input circuit has a polarity reversal suppressor diode and output circuit. It has a free running circuit to avoid overload and short-circuit. It consumes 24 VDC and has a typical response time of approximately 500 micro-seconds. It has 15 VDC - 30 VDC input voltage range ""1"" signal and each channel consumes 3 milli-Amps of current. Coupler offers 24 VDC of output and 2 Amp of current per module. It features inductive nominal load of 12 VA and offers 500 Amps of current per channel. It has 12 Watts of lamp and ohmic nominal load. It operates under 95% humidity and 80 - 106 kPa of air pressure.

Coupler measures 80 mm x 71.5 mm x 119.8 mm. It features a lokalbus field bus system that has transmission speed of 500 kilo-bit/second or 2 mega-bit/second. It has a in-line local bus as designation and is connected using in-line data jumper. It also features modbus/RTU field bus system and has transmission speed of 500 kbit/second or 2 Mbit/second. It has modbus/RTU as designation and is connected using D-SUB-9 female connector. It also has supply designation and is connected using 8-position in-line connector. It is stored/transported at an ambient temperature of -45 to 85 deg C, 95% humidity and 70 kPa - 106 kPa of air pressure.
feature#1 Size: 80 mm Width x 71.5 mm Depth x 119.8 mm Height
feature#2 Lokalbus: Inline data jumper connection, 500 KBPS/2 MBPS transmission speed; modbus/RTU: D-SUB-9 female connector connection, 1,2 - 115,2 KBPS, 9 positions
feature#3 Input: polarity reversal suppressor diode, output: short-circuit and overload protection free running circuit
feature#4 Complete with I/O connectors
feature#5 8 maximum number of devices with parameter channel
feature#6 Input: polarity reversal suppressor diode, output: short-circuit and overload protection free running circuit
feature#7 Load: 12 VA nominal inductive, 12 Watt nominal lamp and ohmic
feature#8 Complete with I/O connectors