Phoenix Contact Phoenix 3031746 Feed-Thru Terminal Block; 24 Amp, 800 Volt, Spring-Cage Connection, NS 35/7.5, NS 35/15 DIN Rail Mount, Polyamide, Gray

*Images are representative of products listed and may not be actual product.

     

AVAILABILITY

Ready to Ship
413


Need more? Additional inventory ships in 10 business days.


Add to Shopping List

Your Price
$2.51 / each


 
Vendor: Phoenix Contact
Cat #: 3031746
Part #: 17849
SKU: 393718
UPC #: 012596000005

Product Details

Size: 51 mm Length x 5.2 mm Width
Ground terminal blocks of the same shape are available
DIN EN 50274 (VDE 0660-514):2002-11 Shock protection test specification
3.12g, 30g Acceleration

Phoenix 2-Pole Feed-thru terminal block in gray color is made of polyamide for durability. It measures 51 mm x 5.2 mm. It has a voltage drop of less than equal to 3.2 milli-Volts, 2 kilo-Volts power frequency to withstand a voltage setpoint of 1 N. It has 5 N, 50 N, 60 N tractive force setpoint, 2.5 sq.mm/4 sq.mm conductor cross section for short circuit testing and testing frequency of 5 - 250 Hz. Block can accommodate solid conductor of size 28 - 12 AWG/stranded conductors of size 28 - 14 AWG and has 10 mm long strip wire.

Block has a surge voltage protection of 8 kilo-Volts, current rating of 24 Amps, short-time current rating of 0.3 kilo-Amps/0.48 kilo-Amps and voltage rating of 800 Volts. Block can be NS 35/7.5, NS 35/15 DIN rail mounted and has spring-cage type connection. It has a load rating of 28 Amps with a conductor cross section of 4 sq.mm and can withstand a temperature of 125 deg C. Block meets IEC 60947-7-1 standards and inflammability rated at UL 94 V0.

Product Specifications

Amperage Rating 24 Amp (Lower Level)
Case Quantity 1, 50
Color Gray
Conductor Range 28-12 AWG Solid, 28-14 AWG Stranded
Connection Spring-Cage
Environmental Conditions Inflammability Rated UL94 V-0, Pollution Degree: 3
In Stock Yes
Item Feed-Through Terminal Block
Load Rating 28 Amp (With 4 Sq mm Conductor Cross Section)
Material Polyamide
Mfr/Vendor Phoenix Contact
Mounting NS 35/7.5,%XA0NS 35, 15 DIN-Rail
Number Of Positions/Contacts 4 Connection
Number Of Terminals 1 Level
Select Code MOTOR CONTROL
ShortDescriptionStripped Phoenix-Contact-Phoenix-3031746-Feed-Thru-Terminal
Standards IEC 60947-7-1
Temperature Rating 125 deg C
UPC 012596000005
Voltage Rating 800 Volt
Wire Strip Length 10 mm
description Phoenix 2-Pole Feed-thru terminal block in gray color is made of polyamide for durability. It measures 51 mm x 5.2 mm. It has a voltage drop of less than equal to 3.2 milli-Volts, 2 kilo-Volts power frequency to withstand a voltage setpoint of 1 N. It has 5 N, 50 N, 60 N tractive force setpoint, 2.5 sq.mm/4 sq.mm conductor cross section for short circuit testing and testing frequency of 5 - 250 Hz. Block can accommodate solid conductor of size 28 - 12 AWG/stranded conductors of size 28 - 14 AWG and has 10 mm long strip wire.

Block has a surge voltage protection of 8 kilo-Volts, current rating of 24 Amps, short-time current rating of 0.3 kilo-Amps/0.48 kilo-Amps and voltage rating of 800 Volts. Block can be NS 35/7.5, NS 35/15 DIN rail mounted and has spring-cage type connection. It has a load rating of 28 Amps with a conductor cross section of 4 sq.mm and can withstand a temperature of 125 deg C. Block meets IEC 60947-7-1 standards and inflammability rated at UL 94 V0.
feature#1 Size: 51 mm Length x 5.2 mm Width
feature#2 Ground terminal blocks of the same shape are available
feature#3 DIN EN 50274 (VDE 0660-514):2002-11 Shock protection test specification
feature#4 3.12g, 30g Acceleration