Eaton / Cutler Hammer BR120 Circuit Breaker; 20 Amp, 120/240 Volt AC, 1-Pole, Plug-On Mount

*Images are representative of products listed and may not be actual product.
  • Eaton / Cutler Hammer BR120 Eaton / Cutler Hammer BR120 Circuit Breaker; 20 Amp, 120/240 Volt AC, 1-Pole, Plug-On Mount
Manufacturer: Eaton / Cutler Hammer
Catalog#: BR120
Crescent Part#: 68746
UPC: 786676362108
Your Price:

Product Details

Dimension: 3 Inch Length x 1 Inch Width x 3 Inch Height

HACR rated

Switch duty rated

Operated by toggle-type handle and multi-pole circuit breakers have an internal common trip mechanism

Handle position provides visual trip position

Product Details:

Eaton 1-Pole Circuit breaker features thermal magnetic molded case for extra protection. Circuit breaker has current rating of 20 Amps and voltage rating of 120/240 VAC. It has AIC rating of 10 kilo-Amps and accommodates copper/aluminum wire of size 14 - 4 AWG at 60 or 75 deg C.

The 1-Phase circuit breaker measures 3 Inch x 1 Inch x 3 Inch. It is ideal for lighting fixture circuits and protects wiring from overheating or short-circuits. Circuit breaker offers long-time instantaneous trip for superior performance. Circuit breaker meets UL 489/federal spec classification W-C375 standards.

Product Specification

Product Details
Manufacturer Eaton / Cutler Hammer
Catalog# BR120
Product Dimensions & Details
Dimensions W:1'' x H:3'' x L:3''
Height 3.00
Length 3.00
Width 1.00
Shipping Information
Ships Ground. Eligible for expedited shipping Yes
Other Information
Item Circuit Breaker
Mounting Plug-On
Dimension 3 Inch Length x 1 Inch Width x 3 Inch Height
Phase 1
Number Of Poles 1
Amperage Rating 20 Amp
Application For Type BR Loadcenters
Brand Name Eaton / Cutler Hammer
Interrupt Rating 10 Kilo-Amp
Wire Size 14-4 AWG (Aluminum/Copper)
Voltage Rating 120/240 Volt AC
Standards UL 489, Federal Spec Classification W-C375
Temperature Rating 60 to 75 deg C
Trip Type Thermal-Magnetic

Customer Questions & Answers

Ask your questions, share your answers.
We respect your privacy. Specify email and we will send the answer to your address. We never reveal your information or use it to send you not related email.
 
I have a 20 amp Cutler-Hammer Type BR120 circuit breaker on my electrical heat tracing sister. Problem: the circuit breaker trips as soon a power is applied. The breaker cannot cope with the initial high current requirements of the electrical tracing (positive temperature coefficient). Once the tracing reaches equilibrium the normal current flow is 11 1/2 amps. Question: What is the correct circuit breaker for this application? Regards, Jim Fugitt
The correct Circuit breaker required would be calculated as follows : 11.5Amps times 200% which would be 23amps I would go with a Cutler Hammer BR125 (25 amp breaker) and you should be good to go.
100% of 0 people found this useful. Was this useful? yes (0) | no (0)