Sign in or register to view your pricing and inventory.

I2000-FLEX FLUKE AC CURRENT CLP I2000

Manufacturer: Fluke
Mfr. #: I2000-FLEX
Item #: 327029
UPC: 095969345088
Availability:
Generally ships in 7-10 business days.

Your Price

$471.9900 / each

Product Details

Detailed Description: I2000-FLEX FLUKE AC CURRENT CLP I2000

Product Specification

Dimensions 4.56 IN Height X 2.69 IN Width X 1.18 IN Depth
Amperage Rating 20/200/2000
Application For Use With Multimeters, Recorders Or Data Loggers
Brand Fluke
Catalog Description AC Current Clamp, Model: i2000, Amperage Rating: 20/200/2000 AMP, Voltage Rating: 600 VRMS/VDC, Measuring Range: 20/200/2000 AMP AC RMS At Current, 10 HZ - 20 KHZ (-3 DB) At Frequency, Operating Temperature: 0 - 70 DEG C (Head And Electronics), Dimensions: 4.56 IN Height X 2.69 IN Width X 1.18 IN Depth, Impedance: 100 KOHM Minimum, Battery: (2) AA/MN 1500/LR6 Alkaline, Accuracy: 25 DEG C, Plus/Minus 1 PCT Of Range 45 - 65 HZ, Diameter: 178 MM Maximum Conductor 14.3 MM Head Cable, Storage Temperature: -40 To 105 DEG C (Head), -20 To 85 DEG C (Electronics), EN 61010-031: 2002, EN 61010-2-032: 2002, EN 61010-1: 2001, 600 VRMS, Category III, EN 61326: 1998 And A1, A2 And A3, For Use With Multimeters, Recorders Or Data Loggers
GTIN

00095969345088

Height 1.9700
Height Unit IN
Item Status A
Length 9.0600
Length UOM IN
Measuring Range 20/200/2000 AMP AC RMS At Current, 10 HZ - 20 KHZ (-3 DB) At Frequency
Mfr. # I2000-FLEX
Model i2000
Operating Temperature 0 - 70 DEG C (Head And Electronics)
Ships Freight No
Ships Ground. Eligible for expedited shipping Yes
Special Features The i2000 is an AC current probe utilizing the Rogowski principle; It can be used to measure currents up to 2000 AMP when used in conjunction with multimeters, recorders or data loggers; The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas; Ideal for current measurement on thick and hard to reach conductors without breaking the circuit; Output sensitivity (AC-coupled): 1/10/100 MILV, 1 MILV/AMP; Linearity: 10 - 100 PCT of range plus/minus 0.2 PCT of reading; Noise 8 MILV AC RMS (30 AMP) 2 MILV AC RMS (300/3000 AMP); Phase error: Less than plus/minus 1 DEG (45 - 65 HZ), plus/minus 10 DEG (at 20 KHZ); Position sensitivity with cable greater than 25 MM from the coupling plus/minus 2 PCT of range; External field with cable greater than 200 MM from the head plus/minus 1 PCT of range; Battery life 200 HR, low battery indicator; Temperature coefficient: plus/minus 0.08 PCT of reading per DEG C; Head Circumference 610 MM; Head bend radius 38.1 MM; Output connection: Molded 4 MM safety plugs (not integrated); Operating humidity 15 - 85 PCT (non-condensing); Weight: 6.34 OZ (head), 6.7 OZ (electronics); Pollution degree: 2; 2 MR length cable
Standard EN 61010-031: 2002, EN 61010-2-032: 2002, EN 61010-1: 2001, 600 VRMS, Category III, EN 61326: 1998 And A1, A2 And A3
Type AC Current Clamp
UNSPSC 41113601
Voltage Rating 848.528//600
Width 6.2000
Width UOM IN